Vulmon
Recent Vulnerabilities
Research Posts
Trends
Blog
About
Contact
Vulmon Alerts
By Relevance
By Risk Score
By Publish Date
schneider-electric igss data server vulnerabilities and exploits
(subscribe to this query)
9.8
CVSSv3
CVE-2022-24324
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Products: IGSS Data Server - IGSSdataServer.exe (Ver...
Schneider-electric Interactive Graphical Scada System
9.8
CVSSv3
CVE-2022-2329
A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. Affected Products: IGSS Data Server - IGSSdat...
Schneider-electric Interactive Graphical Scada System
9.8
CVSSv3
CVE-2022-32522
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted mathematically reduced data request messages. Affected Products: IGSS D...
Schneider-electric Interactive Graphical Scada System
9.8
CVSSv3
CVE-2022-32523
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted online data request messages. Affected Products: IGSS Data Server - IGS...
Schneider-electric Interactive Graphical Scada System
9.8
CVSSv3
CVE-2022-32524
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted time reduced data messages. Affected Products: IGSS Data Server - IGSSd...
Schneider-electric Interactive Graphical Scada System
9.8
CVSSv3
CVE-2022-32525
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted alarm data messages. Affected Products: IGSS Data Server - IGSSdataServ...
Schneider-electric Interactive Graphical Scada System
9.8
CVSSv3
CVE-2022-32526
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted setting value messages. Affected Products: IGSS Data Server - IGSSdataS...
Schneider-electric Interactive Graphical Scada System
9.8
CVSSv3
CVE-2022-32527
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted alarm cache data messages. Affected Products: IGSS Data Server - IGSSda...
Schneider-electric Interactive Graphical Scada System
9.8
CVSSv3
CVE-2022-32529
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted log data request messages. Affected Products: IGSS Data Server - IGSSda...
Schneider-electric Interactive Graphical Scada System
9.8
CVSSv3
CVE-2022-24311
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by inserting at beginning of file or create a new file in the context of the Data Server potentially leading to remote code execution when ...
Schneider-electric Interactive Graphical Scada System Data Server
CVSSv3
CVSSv2
CVSSv3
VMScore
Recommendations:
CVE-2020-4463
CVE-2024-3400
deserialization
CVE-2024-21788
CVE-2023-42433
CVE-2024-21841
CVE-2024-22095
local file inclusion
memory leak
Vulnerability Notification Service
You don’t have to wait for vulnerability scanning results
Get Started
1
2
3
NEXT »